C Wash System

Cumminscorp has developed and produced a high tech water treatment system that is able to intake run off from car wash systems, which contain oil, dirt and chemicals and output clean recycled reusable water. It is a cost efficient, chemical free process.

At present the car wash industry spends millions of dollars a year on purchasing water and disposing of this water after use. The C Wash system presents a cost saving to this industry as car wash owners will now be able to reuse water that would have previously gone to waste. this will not only save money, but give the car wash industry an environment friendly reputation and make them a leader in times of great water hardship.
Traditionally, car wash water recycling facilities were large cumbersome machines that could use large amounts of energy and chemicals in attempting to remove the already existing chemicals as well as detergent run off. These systems generally had high maintenance requirements, and required a large amount of space to house them.

Depending on intake and waste output, the C Wash can be adapted to the specific business that it is required form with water volume always being the main consideration.

The independent tests below were done by Griffith University.

 

C Wash
C Wash
Before & After
Cumminscorp
C-Clean C-Wash C Horse C-Box C-Tank
Clear River
Solutions
Line
Water Remediation
Industrial Water
Aquaculture
Water Tanks
Line
Environment
News
C Technology
Contact Us
Resources

 

Heavy Metal
Original
Test 1
Test 2
pH Value
6.82
7.26
7.29
Dissolved solids
360 mg/l
288 mg/l
296 mg/l
Suspended solids
66 mg/l
27 mg/l
26 mg/l
Chloride
81 mg/l
82 mg/l
76 mg/l
Aluminium
1.58 mg/l
0.26 mg/l
0.25 mg/l
Arsenic
0.002 mg/l
less than 0.001 mg/l
less than 0.001 mg/
Chromium
0.037 mg/l
0.009 mg/l
0.013 mg/l
Copper
0.704 mg/l
0.170 mg/l
0.157 mg/l
Manganese
0.282 mg/l
0.156 mg/l
0.157 mg/l
Nickel
0.031 mg/l
0.018 mg/l
0.018 mg/l
Tin
0.058 mg/l
0.010 mg/l
0.010 mg/l
Zinc
0.772 mg/l
0.223 mg/l
0.199 mg/l

The above results were achieved with the previous model of the C Clean System. This unit did not have the Ozonation or UV Sterilisation attachment for extra germ killing power.